| Test Principle | Variable Frequency Resonant Circuit |
|---|---|
| Usage | On-site AC Withstand Voltage Test |
| Design Feature | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
| Component | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
| Test Frequency | 30-300Hz |
| Usage | Auto And Continuous Print Cable Plate Or Lable |
|---|---|
| Printing Method | Thermal Transfer |
| Feeding Mode | Automatic And Continuous Feeding Plate Or Single And Manual Feeding Plate |
| Maximum Capacity Of Plate Feeding Cassette | Total Thickness Of All Plates ≤ 50mm, 50 Pieces Once (1mm/piece), And The Plate Feeding Cassette Is Dis-mountable, Also Realizing Single And Manual Plate Feeding |
| Max Effective Printing Width | 57mm |
| Product Name | Overhead Line Grounding Fault Location Set |
|---|---|
| Appilcation | Solution Of The Pinpointing Of Single Phase To Earth Fault |
| Special For | Applies To Overhead Line Small Current Grounding Power System |
| Used To | Use To Pinpoint The Earth Fault When Line Break Down When Single Phase Grounding Fault Happen |
| High Light | Underground Cable Detector, High Voltage Cable Identifier |
| Product Name | Cable Tracing Tester |
|---|---|
| Appilcation | Cable Locate Trace And Depth Detecting |
| Woking Freq | 500Hz , 1kHz, 8kHz, 33kHz, 66kHz, 93kHz |
| Max.Voltage | Max.200V (AC Peak Value) |
| Power Supply | Built-in Rechargeable Lithium Battery |
| Product Name | Cable Or Pipe Line Tracing Tester |
|---|---|
| Appilcation | Support POWER–ON Locating Cable |
| Tracing Way | Left / Right Arrow Indicate Cable Route Tracing |
| Advantage | Intelligent Clamp Detecting, To Show Right/wrong Directly |
| Feature | Easy Radiation Detecting ,Intelligent Pinpoint Sheath Fault Locating, Pinpointing |
| Product Name | Live Cable Identification Tester |
|---|---|
| Appilcation | High Voltage Cable Phase Sequence Identification |
| Output Signal | Sinusoidal AC Signals Of Four Frequencies, Namely Low Frequency, Intermediate Frequency, High Frequency And Radio Frequency. |
| Output Power | Constant Power Output, Low, Medium And High Three |
| Tracing Mode | Direct Connection Method, Coupling Method |
| Product Name | Cable Fault Distance Locator |
|---|---|
| Appilcation | Cable Fault Locating And Underground Path Tracing |
| Cable Class | No More Than 35KV |
| Detecting Way | LV Impulse Method, Impulse HV Flash-over Method, Multiple Pulse Method |
| Fault Locating Error | ±0.2m |
| Usage | Insulation Resistance Test And Analyzing |
|---|---|
| Special For | Large Transformers, Generators, High-voltage Motors |
| Ouput Voltage | 50V、100V、250 V、500V、1.0kV、2.5kV、5.0kV、10.0kV |
| Range | 0 ~10TΩ |
| Short Circuit Current | No Less Than 5mA |
| Usage | Underground Cable Detector , Cable Line Short Circuit Fault Diagnosis |
|---|---|
| High Light | Ac High Voltage Test Set, High Voltage Cable Identifier |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Delivery Time | 10 work days |
| Payment Terms | T/T |
| Product Name | Unpowered Cable Identification Tester |
|---|---|
| Appilcation | High Voltage Cable Phase Sequence Identification |
| High Light | Ac High Voltage Test Set, Underground Cable Detector |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Delivery Time | 10-15 Working Days |