Test Principle | Variable Frequency Resonant Circuit |
---|---|
Usage | On-site AC Withstand Voltage Test |
Design Feature | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency | 30-300Hz |
Usage | Auto And Continuous Print Cable Plate Or Lable |
---|---|
Printing Method | Thermal Transfer |
Feeding Mode | Automatic And Continuous Feeding Plate Or Single And Manual Feeding Plate |
Maximum Capacity Of Plate Feeding Cassette | Total Thickness Of All Plates ≤ 50mm, 50 Pieces Once (1mm/piece), And The Plate Feeding Cassette Is Dis-mountable, Also Realizing Single And Manual Plate Feeding |
Max Effective Printing Width | 57mm |
Product Name | Overhead Line Grounding Fault Location Set |
---|---|
Appilcation | Solution Of The Pinpointing Of Single Phase To Earth Fault |
Special For | Applies To Overhead Line Small Current Grounding Power System |
Used To | Use To Pinpoint The Earth Fault When Line Break Down When Single Phase Grounding Fault Happen |
High Light | Underground Cable Detector, High Voltage Cable Identifier |
Product Name | Cable Tracing Tester |
---|---|
Appilcation | Cable Locate Trace And Depth Detecting |
Woking Freq | 500Hz , 1kHz, 8kHz, 33kHz, 66kHz, 93kHz |
Max.Voltage | Max.200V (AC Peak Value) |
Power Supply | Built-in Rechargeable Lithium Battery |
Product Name | Cable Or Pipe Line Tracing Tester |
---|---|
Appilcation | Support POWER–ON Locating Cable |
Tracing Way | Left / Right Arrow Indicate Cable Route Tracing |
Advantage | Intelligent Clamp Detecting, To Show Right/wrong Directly |
Feature | Easy Radiation Detecting ,Intelligent Pinpoint Sheath Fault Locating, Pinpointing |
Product Name | Live Cable Identification Tester |
---|---|
Appilcation | High Voltage Cable Phase Sequence Identification |
Output Signal | Sinusoidal AC Signals Of Four Frequencies, Namely Low Frequency, Intermediate Frequency, High Frequency And Radio Frequency. |
Output Power | Constant Power Output, Low, Medium And High Three |
Tracing Mode | Direct Connection Method, Coupling Method |
Product Name | Cable Fault Distance Locator |
---|---|
Appilcation | Cable Fault Locating And Underground Path Tracing |
Cable Class | No More Than 35KV |
Detecting Way | LV Impulse Method, Impulse HV Flash-over Method, Multiple Pulse Method |
Fault Locating Error | ±0.2m |
Usage | Insulation Resistance Test And Analyzing |
---|---|
Special For | Large Transformers, Generators, High-voltage Motors |
Ouput Voltage | 50V、100V、250 V、500V、1.0kV、2.5kV、5.0kV、10.0kV |
Range | 0 ~10TΩ |
Short Circuit Current | No Less Than 5mA |
Usage | Underground Cable Detector , Cable Line Short Circuit Fault Diagnosis |
---|---|
High Light | Ac High Voltage Test Set, High Voltage Cable Identifier |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Delivery Time | 10 work days |
Payment Terms | T/T |
Product Name | Unpowered Cable Identification Tester |
---|---|
Appilcation | High Voltage Cable Phase Sequence Identification |
High Light | Ac High Voltage Test Set, Underground Cable Detector |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Delivery Time | 10-15 Working Days |