| Test Principle | Variable Frequency Resonant Circuit |
|---|---|
| Rated Capacity | 400kVA |
| Design Feature | Portable Type |
| Test Frequency | 30-300Hz |
| Duty Cycle | 60 Mints |
| Test Principle | Variable Frequency Resonant Circuit |
|---|---|
| Usage | AC Hipot Test And Induced Withstand Voltage Test |
| Application | HV Power Transformer,GIS,Power Substation |
| Test Frequency | 50Hz |
| Test Accuracy | No Less Than 1.0% |
| Test Principle | Variable Frequency Resonant Circuit |
|---|---|
| Rated Capacity | 108kVA |
| Design Feature | Portable Type |
| Test Frequency | 30-300Hz |
| Duty Cycle | 15min |
| Test Principle | Power Frequency Test Transformer Circuit |
|---|---|
| Test Standard | IEC60060-1:2010 |
| Max.capacity | 500KVA |
| Max. Voltage | 500KV |
| Usage | AC Hipot Test In The Factory Quality Inspection For Power Transformers, Gas-insulated Switchgears, Bushings, Arresters And Insulation Materials |
| Usage | Measurement And Control Unit For Power Frequency AC Withstand Voltage Test Circuit. |
|---|---|
| Advantage | Good Protections And Good Monitoring Functions |
| Operation Way | Double Control Way , PLC Computer Control Or Manual Button Control |
| Speical For | Replace The Old Traditional Console To Increase The Efficiency |
| Max.Control Voltage | No Limit, Made By Order |
| Used Field | Electrical Test Apparatus For AC Hipot Testing |
|---|---|
| Application | AC High Voltage Test And Leakage Current Measurment |
| Max. Test Voltage | 20KV, 30KV, 50KV , 60KV, 80KV, 100KV Optional |
| Max. Output Capacity | 3KVA,5KVA, 6KVA,8KVA,10KVA, 15KVA Optional |
| Duty Cycle | Short Time Working Within 5mints |
| Used Field | Electrical Test Apparatus For AC Hipot Testing |
|---|---|
| Application | Compensation High-voltage Test Current |
| Max. Test Voltage | 30KV , 25KV , 20KV Three Output Taps |
| Max. Output Capacity | 300mA, 250mA, 150mA |
| Duty Cycle | Within 5mints At Rated Capacity |
| Used Field | Electrical Test Apparatus |
|---|---|
| Application | AC High Voltage Test And Leakage Current Measurment |
| Output Range | 50KV And 100mA Or OEM |
| Advantage | Large Power Output, Portable, Lighter |
| Duty Cycle | Short Time Working Within 5mints |
| Used Field | Electrical Test Apparatus |
|---|---|
| Application | AC High Voltage Test And Leakage Current Measurment |
| Test Range | 80KV And 100mA |
| Advantage | Large Power Output, Portable, |
| Duty Cycle | Short Time Working Within 5mints |
| Used Field | Electrical Test Apparatus |
|---|---|
| Application | AC High Voltage Test And Leakage Current Measurment |
| Output Range | 50KV And 60mA Or OEM |
| Advantage | Large Power Output, Portable, Lighter |
| Duty Cycle | Short Time Working Within 5mints |