Send Message

Ningbo Suntech Power Machinery Tools Co., Ltd.

Professional Manufacturer and Exporter of Electric Power Field

Home ProductsHigh Voltage Cable Testing Equipment

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

  • Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity
Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity
Product Details:
Place of Origin: Ningbo,China
Brand Name: Ningbo Suntech Power
Certification: ISO9001
Model Number: CHX-3000KVA/150KV
Payment & Shipping Terms:
Minimum Order Quantity: One Unit
Price: Negotiable
Packaging Details: Export Standard Wooden Case With Fumigation Free
Delivery Time: 25~35 Working Days
Payment Terms: L/C, T/T
Supply Ability: 10sets / 2months
Contact Now
Detailed Product Description
Test Principle: Variable Frequency Resonant Circuit Usage: AC Withstand Voltage Test For HV Cable Or GIS
MAX.Capacity: 3000KVA Or OEM Max.Voltage: 150KV Or OEM
Test Frequency: 20-300Hz Duty Cycle: 60 Mints Or OEM
Test Accuracy: No Less Than 1.5% Special For: On-site Test For Long HV XLPE Cable And GIS
Test Standard: IEC 60060-1:2010;IEC 60840:2011 And IEC 62067:2011 For XLPE Cable
High Light:

3000KVA Cable Testing Device

,

XLPE Cable Testing Device

,

XLPE Cable Hv Test Equipment

Variable Frequency Resonant Withstand Voltage Test Reactor For Long HV XLPE Cable

 

I. Application :


The high voltage test reactor is HV booster or generator in the variable frequency resonant withstand voltage circuit, it has large capacity and HV for one piece with higher Quality factor putput . it is special for the high voltage XLPE cable test with longer distance .

 

Fanke company can finish the design and produce the goods according to all kinds of customer's requirement . such as cylinder type and iron tank type .

 

Test reactor can be produced to be 130KV,150KV,155KV,200KV, 250KV, 300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~5A,10A,15A,20A,25A,30A.

 

II. Test priciple figure:
Portable Variable Frequency Resonant Withstand Voltage Test Set

VF: Variable Frequency Power Supply Source which is control and measurement part in the test circuit.

T : Excitation Transformer which provide the exciting voltage for HV test reactor
L : Test Reactor which is resonant inductance in the LC circuit and produce the test voltage

Cx: Tested Equipment

MOA1: Lightning Arrestor is protection part on the excitation transformer
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm ) which is HV voltage measurement part


III. General Technical data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : OEM
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Number of HV test reactor: OEM
  5. Rated output capacity: OEM
  6. Rated output Voltage: 150KV or OEM
  7. Max Test voltage : no more than 150KV,300KV,450KV
  8. Rated output current: 25A max or OEM
  9. Reg. Freq range : 20Hz-300Hz
  10. Output Resonance voltage waveform: sine wave
  11. THD of output waveform: ≤1%
  12. Insulation level: Under 1.1 times and keeping 1min, normal
  13. Duty cycle : 60mins on under rated current working condition ;
  14. Quality factor of test set itself: Q≥60
  15. Temperature rise: Less than 65K under rated current working 60mints;
  16. Noise level: No more than 65dB
  17. Reactor Structure: oil immersed type, epoxy tube cylinder type;

 

IV.Accessories

  • Necessary corona rings
  • Parallel cables of the reactor
  • HV output cables(reactor to divide)
  • Corona ring for test reactor
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


V. Typical model of test reactors

 

1 Optional model for 132KV class XLPE cable on-site withstand voltage test

 

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-775KVA/155KV 155KV 5A 775KVA 132kV cable≤1km
CHX-1550KVA/155KV 155KV 10A 1550KVA 132kV cable≤2km
CHX-2325KVA/155KV 155KV 15A 2325KVA 132kV cable≤3km
CHX-3100KVA/155KV 155KV 20A 3100KVA 132kV cable≤4km
CHX-3875KVA/155KV 155KV 25A 3875KVA 132kV cable≤5km
CHX-7750KVA/155KV 155KV 50A 7750KVA 132kV cable≤10km
CHX-12400KVA/155KV 155KV 80A 12400KVA 132kV cable≤16km
CHX-15500KVA/155KV 155KV 100A 15500KVA 132kV cable≤20km
Special requirement can be made by order

Note :Tested cable voltage class≤ 132kV, 0.25uF/km

 

2 Optional model for 230KV class XLPE cable on-site withstand voltage test

 

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-2020KVA/255KV 255KV 8A 2020KVA 220~230kV cable≤1km
CHX-4080KVA/255KV 255KV 16A 4080KVA 220~230kV cable≤2km
CHX-6120KVA/255KV 255KV 24A 6120KVA 220~230kV cable≤3km
CHX--8160KVA/255KV 255KV 32A 8160KVA 220~230kV cable≤4km
CHX--10200KVA/255KV 255KV 40A 10200KVA 220~230kV cable≤5km
CHX--20400KVA/255KV 255KV 80A 20400KVA 220~230kV cable≤10km
CHX--25500KVA/255KV 255KV 100A 25500KVA 220~275kV cable≤12.5km
Special requirement can be made by order

Note :Tested cable voltage class≤ 230kV, 0.25uF/km

 

3 Optional model for 330KV class XLPE cable on-site withstand voltage test

 

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-3500KVA/350KV 350KV 10A 3500KVA 330kV cable≤1km
CHX-7000KVA/350KV 350KV 20A 7000KVA 330kV cable≤2km
CHX-10500KVA/350KV 350KV 30A 10500KVA 330kV cable≤3km
CHX-14000KVA/350KV 350KV 40A 14000KVA 330kV cable≤4km
CHX-21000KVA/350KV 350KV 60A 21000KVA 330kV cable≤5km
CHX-28000KVA/350KV 350KV 80A 28000KVA 330kV cable≤10km
Special requirement can be made by order

Note :Tested cable voltage class≤ 330kV, 0.25uF/km

 

4 Optional other model for long XLPE cable on-site withstand voltage test

 

Model Rated voltage Rated output current Rated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV 130KV 10A,20A 1300KVA For U0=64KV and below cable
CHX-3000KVA/150KV 150KV 10A, 20A 3000KVA For U0=87KV and below cable
CHX-10000KVA/250KV 250KV 20A, 40A 10000KVA For U0=127KV and below cable
CHX-20000KVA/250KV 250KV 20A, 80A 20000KVA For U0=127KV and below cable
CHX-21000KVA/350KV 350KV 20A, 60A 21000KVA For U0=230KV and below cable
CHX-42000KVA/350KV 350KV 20A, 80A 42000KVA For U0=230KV and below cable
Special requirement can be made by order

Note : XLPE cable test voltage is considering as 1.7U0

 

5 Optional model for HV or EHV class cable and GIS On-site AC hipot test

 

Model Rated voltage Rated output current Rated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV,260KV 130KV,260KV 20A@130KV 2600KVA

For U0=64KV cable

For 72.5KV class GIS

10A@260KV

For U0=127KV cable

For 145KV class GIS

CHX-9000KVA/150KV,300KV 150KV,300KV 60A@150KV 9000KVA

For U0=87KV cable

For 72.5KV class GIS

30A@300KV

For U0=160KV cable

For 170KV class GIS

CHX-10000KVA/250KV,500KV 250KV,500KV 40A@250KV 10000KVA

For U0=127KV cable

For 145KV class GIS

20A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-20000KVA/250KV,500KV 250KV,500KV 80A@250KV 20000KVA

For U0=127KV cable

For 145KV class GIS

40A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-21000KVA/350KV,700KV 350KV,700KV 60A@350KV 21000KVA

For U0=190KV cable

For 170KV class GIS

30A@700KV

For U0=290KV cable

For 550KV class GIS

Special requirement can be made by order

 

 

VI. On-site test standard table from IEC 60840:2011 and IEC 62067:2011 for XLPE cable

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 1

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 2

VII. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 3

Contact Details
Ningbo Suntech Power Machinery Tools Co.,Ltd.

Contact Person: Peter

Tel: 86-13958364836

Send your inquiry directly to us
Other Products