Place of Origin: | Ningbo,China |
Brand Name: | Suntech |
Certification: | ISO |
Model Number: | Stringing Block 660mm |
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiation |
Packaging Details: | Exported Box and Containers |
Delivery Time: | 10-15 days after Payment |
Payment Terms: | L/C , T/T, Western Union |
Supply Ability: | 2000 pcs per month |
Name: | Conductor Stringing Block | Diameter Of Wheels: | 660 |
---|---|---|---|
Number: | 1,3,5,7 | Material: | MC Nylon Sheave And Steel Support |
Application: | Power Transmission | Usage: | Construction Works |
High Light: | SF6 3 Phase Circuit Breaker,Pneumatic Arc Extinguishing Chamber Circuit Breaker,SF6 Three Phase Circuit Breaker |
660mm MC Nylon Overhead Line Cable Conductor Stringing Blocks Pulley
Application: It is suitable to string stranded aluminum and ACSR conductors on tangent structures.Compression sleeves, swivel connectors, and
pulling rope connectors can pass through the groove. The sheave is made in aluminum alloy or high strength nylon. The big size 508mm, 660mm
aluminum alloy sheave can be lined with neoprene. The big size 660mm, 822mm, 916mm, 1040mm nylon sheave can be lined with neoprene.
Single sheave Nylon Stringing Block
Item No. | Model | ACSR Size Range (mm²) | Working Load (KN) | Weight (kg) | Material of Sheave |
10191 | SHDN-120x30 | 25-70 | 5 | 1.5 | Nylon |
10192 | SHDN-160x40 | 70-95 | 10 | 2.4 | |
10193 | SHDN-200x40 | 95-120 | 15 | 2.6 | |
10194 | SHDN-200x60 | 120-150 | 15 | 3.1 | |
10195 | SHDN-250x40 | 120-150 | 20 | 3.7 | |
10196 | SHDN-250x60 | 150-180 | 20 | 3.9 | |
10197 | SHDN-270x60 | 180-240 | 20 | 4.4 | |
10198 | SHDN-320x60 | 240-300 | 20 | 7.5 | |
10199 | SHDN-400x80 | 300-400 | 20 | 8 | |
10104 | SHDN508 | 300-400 | 20 | 16 | Nylon, optional can be lined with neoprene |
10124 | SHDN660 | 400-500 | 20 | 24 | |
10131 | SHDN750 | 500-600 | 30 | 32 | |
10141 | SHDN822 | 600-700 | 30 | 38 | |
10151 | SHDN916 | 700-800 | 50 | 51 | |
10165 | SHDN1040 | 800-900 | 50 | 60 |
Application: It is suitable to string stranded aluminum and ACSR conductors on tangent structures. Compression sleeves,
swivel connectors, and pulling rope connectors can pass through the groove
Overhead Transmission Line Large Diameter Stringing Blocks
Item No. | Model | No. of Sheaves | Rated Load (KN) |
Diameter of Groove / Conductor Size |
Weight (kg) | Material | Outer Dia. / width Of Sheave |
10101 | SHD-508x75 | 1 | 20 | Φ408mm / ≤ACSR400 mm² | 22.5 | Aluminum |
Φ508mm / 75mm
|
10102 | SHS-508x75 | 3 | 40 | 86 | Central sheave steel | ||
10103 | SHW-508x75 | 5 | 60 | 108 | |||
10104 | SHDN-508x75 | 1 | 20 | 18.5 | Nylon | ||
10105 | SHSLN-508x75 | 3 | 40 | 51.5 | Central sheave Nylon | ||
10106 | SHWLN-508x75 | 5 | 60 | 91.5 | |||
10107 | SHSQN-508x75 | 3 | 40 | 60 | Nylon | ||
10108 | SHWQN-508x75 | 5 | 60 | 75 | |||
10121 | SHD-660x100 | 1 | 20 | Φ560mm / ACSR400 - 500 mm² | 30 | Aluminum |
Φ830mm / 110mm
|
10122 | SHS-660x100 | 3 | 40 | 106 | Central sheave steel | ||
10123 | SHW-660x100 | 5 | 60 | 136 | |||
10124 | SHDN-660x100 | 1 | 20 | 20 | Nylon | ||
10125 | SHSN-660x100 | 3 | 40 | 92 | Central sheave Nylon | ||
10126 | SHWN-660x100 | 5 | 60 | 120 | |||
10127 | SHSQN-660x100 | 3 | 40 | 85 | Nylon | ||
10128 | SHWQN-660x100 | 5 | 60 | 100 | |||
10141 | SHDN-822x110 | 1 | 30 | Φ710mm / ACSR500 - 630 mm² | 25 | Nylon |
Φ916mm / 110mm
|
10142 | SHSQN-822x110 | 3 | 60 | 130 | Central sheave Nylon | ||
10143 | SHWQN-822x110 | 5 | 90 | 180 | |||
10144 | SHSQN-822x110 | 3 | 60 | 100 | Nylon | ||
10145 | SHWQN-822x110 | 5 | 90 | 130 | |||
10151 | SHDN-916x110 | 1 | 50 | Φ800mm / ACSR720 - 800 mm² | 45 | Nylon | |
10152 | SHSQN-916x110 | 3 | 80 | 140 | |||
10153 | SHWQN-916x110 | 5 | 150 | 235 |
Contact Person: Peter
Tel: 86-13958364836
Dia 660mm Conductor Stringing Blocks , Stringing Equipment For Overhead Power Lines
MC Nylon Cable Pulley Sheaves For Transmission Stringing Pulley Block
Factory Price MC Nylon Conductor Cable Stringing Pulley Block With Hook
High Wind Tolerance Lattice Q355 Q255 Angle Steel Tower
132kv Transmission Line Galvanized Steel Lattice Tower
Polygonal Conical 10kv To 750kv Transmission Line Angle Tower
89kN 33kV Max High Voltage Line Post Insulators
Anti Fouling 240kN Toughened Glass Electrical Insulators
70KN 33KV High Voltage Disc Type Porcelain Suspension Insulator
69KV 10KN Erode Proof High Voltage Polymer Line Post Insulators