Product Details:
Place of Origin: Ningbo,China
Brand Name: Suntech
Certification: ISO
Model Number: ZW32-24
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: Negotiation
Packaging Details: Exported Wooden Case
Delivery Time: 25-30 days after Payment
Payment Terms: L/C , T/T
Supply Ability: 60000 pcs per month
Contact Now
Detailed Product Description
Product Name: Outdoor Vacuum Circuit Breaker Rated Voltage: 24KV
Rated Frequency: 50/60hz Poles Number: 3
BCD Curve: A Altitude: ≤2000m
Ambient Temperature: -40°C-+40°C Wind Speed: 35m/s
Ambient Pllution: IV Earthquake Intensity: ≤ 8 Degre
High Light:

24KV Outdoor Vacuum Circuit Breaker

,

GB1102 Outdoor Vacuum Circuit Breaker

,

24KV Transmission Line Circuit Breaker

24kV Transmission Power Line Outdoor Vacuum Circuit Breaker

 

ZW32-24 type outdoor vacuum circuit breaker is rated voltage 24kV, three-phase AC 50/60Hz outdoor distribution equipment. Mainly used for breaking, closing power system load current, overload current and short circuit Current. For substation and industrial and mining enterprises distribution system protection and control of workplace use, and frequent operation of rural power grids. The circuit breaker vacuum interrupter technique using solid seal, external insulation silicon Rubber sleeve, long life and high relibility, actuator can be miniaturized, highly rliable spring mechanism may also be advanced permanent magnet body. You can also configure isolating switches and itelligent controllers, with But when slicer kind of coincidence Used, enabling four remote functions and distribution automation.

 

Name Unit Data
Rated voltage KV 24
Rated power frequency Hz 50/60
Rated current KA 630
Rated short-circuit breaking current KA 20
Rated peak withstand current(peak) KA 50
Rated short-time withstand current KA 20
Rated short-circuit making current(peak) KA 50
Mechanical life Secondary 10000
Rated short-circuit breaking current breaking times Secondary 30

Power frequency withstand voltage

(1min) :vacuum fracture,white, on the groundfracture

KV 65/79

Lighting impulse withstand votage

(peak) and white, right fracture

KV 125/145

Secondary circuit 1min power

frequency withstand voltage

KV 2

 

Standard

1. GB1984 "AC high voltage circuit breakers"

2. GB1102 "nigh-oltage switch and control equipment standards common technical requirements"

3. GB311.1-6 "insulated high voltage transmission and distribution equipment."

4. GB763 "AC high voltage electrical work in long-term fever"

5. GB2706 "AC high voltage electrical dynamic and thermal stability test methods"

6. GB3309 "high voltage switch at room temperature mechanical test"

7. DL / T593 "common ordering technology high voltage switch"

Ambient condition

1. ambient air temperature: + 40°C ~ -40 °C

2. a height of not more than 2000 meters above sea level

3. the wind speed is not greater than 35m/s

4. anti-contamination level for grade IV

5. the earthquake intensity does not exceed 8 degrees

6. no fire, explosion, severe chemical corrosion of the place

 

GB1102 24KV Transmission Line Outdoor Vacuum Circuit Breaker 0